Energy Storage Boost Converter

Model: Energy Storage Boost Converter
DC Voltage Range: 580~1000V
Max. DC Current: 3750A
Rated AC Power: 2500kW
Max. AC Power: 2750kVA
Rated Grid Frequency: 50Hz

product introduction-yvse.png

储能升压变流一体机-详情图1.png

1.Turnkey Solution

Integrate PV inverter, transformer, and switchgear in one unit, Integral commissioning from the factory, saving time for on-site installation and intermodulation Containerized shell, no need for special spreader, easy transportation and lifting.

2.High Reliability and Safety

Uses epoxy resin cast dry-type transformers, which are flame-resistant products with no explosion or fire hazards. Dry-type transformers have passed C2, E2, and F1 tests conducted by the National Transformer Quality Supervision and Inspection Center.

3.Strong Environmental Adaptability

Strong anti-corrosion capability: The containerized shell uses highly weather-resistant steel plates with better corrosion resistance than regular carbon steel. Thermal insulation: The internal shell is equipped with a heat insulation board, which has good fireproof, heat insulation, and heat preservation effects. Ventilation and heat dissipation: Specially designed air inlets prevent dust and sand effectively.

4.Low Investment, High Returns

Reduce investment by 15% to 20% compared to the conventional "inverter room + photovoltaic box transformer". Reduce the number of installation bases from 2 to 1. Save 50% on installation and commissioning time. Save cables for connection between inverter rooms and photovoltaic box transformers by using copper bars between inverters and transformers, Save two low-voltage switchgear units between inverters and transformers by optimizing structure.

5.Flexible and Diverse Product Solution

Designed to fully meet the actual needs of customers and provide them with satisfactory one-stop solutions.

6.Main Application Scenarios

Scenario One: Energy Storage for Photovoltaic Power Plants. Scenario Two: Wind Power Plant Energy Storage Application

Parameters Table-mrqt.png

储能升压变流一体机-详情图2.png

储能升压变流一体机-详情图3.png

performance features-khpu-eeer.png

The high-voltage side voltage rating can range from 6kV to 35kV. High-voltage switches can be selected based on requirements, including oil-immersed load switches (suitable for distribution transformers), vacuum load switch-fuse combinations, or vacuum circuit breakers. When the project's altitude exceeds 3500 meters, it is generally recommended to opt for SF6 fully insulated ring main units to ensure the safe and reliable operation of the transformer.

Transformer options include units from American Transformer, Chinese Transformer, or dry-type transformers. Currently, ESVB-CUs with transformer capacities of up to 6300kVA are available, and larger capacities can be customized to meet specific customer demands.

Communication protocols for external communication can be customized to meet individual project requirements, as these can vary significantly from site to site. Common communication protocols include Modbus-RTU, Modbus-TCP, CAN2.0B, IEC61850, IEC60870-5-104, and IEC60870-5-103.

Each PCS (Power Conversion System) manufacturer has unique interface locations and types, necessitating the design of a tailored structure for each PCS manufacturer.

The AC measurement voltage level for PCS can range from 0.315kV to 0.69kV. Typically, for PCS AC measurement voltages at or below 0.4kV, the corresponding DC side rated voltage does not exceed DC1000V, and such models are predominantly intended for indoor use. For PCS AC measurement voltages between 0.5kV and 0.69kV, the corresponding DC side rated voltage is generally DC1500V, and these models are designed for outdoor use, often achieving IP54 or higher protection levels.

The ESVB-CU enclosure can be either a container-type enclosure, often custom-sized and fully welded, which tends to be relatively expensive, or a standard assembly-type enclosure, offering cost savings. In most cases, the latter option is recommended for clients.

Currently, the energy storage market predominantly features large-scale projects on both the grid side and the generation side. Contract values for individual energy storage projects with ESVB-CUs can range from millions to tens or even hundreds of millions of dollars.

production ability-nxzw.png

CEEG production ability 61-urml.jpg

Our production base covers an area of more than 600 acres (40 hectares) with extensive facilities and a total construction area of 180,000 square meters. We have a professional team of more than 1,000 employees. We have advanced transformer production and testing equipment here to ensure that we provide customers with high-quality power transformer products.

We boast an array of cutting-edge equipment representing a high standard within the industry, including a complete set of shearing machines, fully automated winding machines, robot-operated stacking machines, the Hedrch Vacuum Casting Equipment, vacuum impregnation systems, air cushion transport vehicles, a fully enclosed production workshop with a cleanliness level of 100,000, 20-ton vertical winding machines, 10-ton horizontal winding machines, coal-oil gas phase drying equipment, and a 200-ton overhead crane. We adopt the latest technology and processes to ensure that our products comply with international standards and customer needs.

We have a strong production capacity of 30 million kVA power transformers per year. This means we can cater to all sizes and types of power transformer needs, from small applications to large energy projects. No matter what specifications our customers require, we deliver them on time and support them with high quality and reliability.

certificates-flsz.png

CEEG certificates 2-evku-bwwv.jpg